TMS 5000


TMS 5000: Long Standoff Non-Contact Thickness Gage





Specifications:



PERFORMANCE:

===========

Accuracy: +/-0.00025" or +/-0.025% of the sum of the distances from the transducers to the target surfaces; whichever is greater for distances up to 5" +/-0.033% from 1.5" up to 4" and +/-0.05% thereafter.

Repeatability: +/-0.05% of the distance from the transducers to the target

Inspection Rate: Variable to 58 measurements per second

Operating Range: 0.2" - 23.999" or 5mm - 609mm (Transducer to target)

Thickness Range:

0.004" - 9.9999" in 0.0001 resolution mode

0.004" - 99.999" in 0.001 resolution mode

0.1mm - 99.999mm in 0.001mm resolution mode

0.1mm - 999.99mm in 0.01mm resolution mode

Off-Axis Alignment: +/- 2.5 to 5 degrees depending on target size, material and range



ELECTRICAL:

=========

Input Power:

100 VAC, 50/60 Hz

120 VAC, 60 Hz

230 VAC, 50 Hz

Maximum Power Consumption: 35 watts

Standard Interfaces: Full duplex asynchronous RS-232C, 3-wire or RS-422A, 5-wire communications interface

Baud Settings: 300, 600, 1200, 2400, 4800, 9600, 19200, none

Word Length: 8 bit; 7 ASCII + 1 Parity Bit

Parity: unused

Stop Bit: 1 stop bit

Line Status: disable

16 bit parallel binary output, TTL Compatible 3mA Source, 20mA Sink

Optional Interface:

Analog: 0-10 VDC or 4-20mA (up to 2500 Ohm load for 4-20mA) Selectable analog span: 00.00" to 99.9999" or 0mm to 999.9mm

Incremental steps of voltage or current within span: 4096 steps



MECHANICAL/ENVIRONMENTAL:

========================

Dimensions and Weight:

Transducer: 5.5"H x 1.5"D .33lbs

Controller: 12"H x 12"W x 7.5"D, 25 lbs Enclosure NEMA 13 Rated

Industrial Air Hood: 11"H x 4.5"W x 4.0"D 5 lbs

Air Fan/Filter: 110V, 15"H x 14"W x 15"D 20 lbs

Temperature: Operating -20 to +50 C

Noise Immunity:

Acoustic: Filtered to eliminate noise spectrum of common industrial environments

Electrical: Shielded for RF/EMI

Humidity: 95% maximum Non-condensing

Transducer to Controller Separation:

Standard: 10'-30' Optional: 500'



PROGRAMMABLE TRANSDUCER CONTROLLER:

==================================

Display: 5 digit LED display on controller

Programming: 2 momentary push button switches on controller provide local programming of parameters. Controller can also be programmed remotely via the RS-232C, RS-422A interface

Signal Compensation: Continuous automatic calibration for temperature changes

Sample Averaging: Programmable from 1 to 4095 samples per measurement

Amplitude Filter: Programmable to filter measurements from vibrating or poorly aligned targets

Run Mode: Programmable for free running or sample on command by switch or contact closure

Relay Configuration: Programmable relay closure in or out of limit set points. Electromechanical SPDT rated 2A maximum, 60 VDC

Relay Thickness Limit Set Points: Programmable high and low relay limit set points for selectable closure, normally-in or normally-out of limits in 0.01 inch increments

Delay to Relay Closure: Programmable relay delay from 0.002 to 65 seconds in 0.002 second increments

Relay Closure Interval: Programmable relay closure interval from 0.002 to 65 seconds in 0.002 second increments